ZEDsatellite

Precise measuring directly at the test object

The ZEDsatellite decentralized measuring and testing modules enable measuring directly at the test object, increasing measuring accuracy and reliability.

The data from the available measuring methods can be easily read out centrally via ZEDbox or any other unit from the ZED device family.

ZEDsatellite from ZELTWANGER

Measuring methods

RD

RD relative pressure (optional: 2-channel)

RD / GP

relative pressure with bell testing

RD / DF

relative pressure with flow rate

DD

differential pressure

MF

mass flow

Accessories (optional)

  • Test leak
  • Leak calibrator
  • External ventilation valve
  • Temperature compensation

ZEDsatellite application examples

  • Automotive: Engines, cylinder heads, gears, diaphragms, auxiliary heaters, power adapters, hybrid drives, heat exchangers, control electronics, batteries, lines, valves, fuel cells, pumps, etc.
  • Medical technology: Catheters, dialysis filters/boxes, flushing/hose systems, secretion containers, syringes, external lung machines, etc.
  • Packaging/cosmetics: Dispensing pumps, plastic bottles, cartridges, etc.
  • Household appliances: Water distributors, water pumps, gas valves/fittings, stoves, compressors, etc.
  • General industry: Cylinders, safety/non-return valves, couplings, grippers, ball valves, seals, throttle pins, etc.

Control unit

Expansion and combination options

ZEDbox 1 external

+ 1 external
max. 2 channels
ZEDbase+ 1 internal

+ 1 external
max. 2 channels
ZEDmod internal

external
max. 8 channels

Interfaces

  • Auxiliary
  • Temperature sensor
  • Interface to the control unit
  • Dimensions (H x W x D): 139 x 235 x 315 mm
  • Weight: approx. 8 – 10 kg
  • Power supply: 24 VDC (+10 / -5%) 5 A
  • Test medium: Compressed air (oil and water-free according to ISO 8573-1 class 3)
Technical data: Relative pressure Differential pressure Accumulation pressure Mass flow Flow rate
Test pressure range Vacuum – 232 psi / 16 bar 0 – 6 bar Vacuum – 116 psi / 6 bar
Test pressure accuracy 1% of the end value 1% of the end value 1% of the end value 1% of the end value
Measuring range As with test pressure range – 1.45 – 1.45 psi – 100 – 100 mbar 10,000 – 450,000 ccm/min | ml/min -50 – 50 or -250 – 250 ccm/min | ml/min up to 250,000 ccm/min | ml/min
Measurement resolution 0.5 ppm of the end value
Smallest measurable pressure change (type-specific) 0.5 Pa (14.50 psi / 1 bar) – 4 Pa (232 psi / 16 bar) 0.1 Pa 0.1 Pa (50 mbar) – 1.5 Pa (6 bar)    
Measuring accuracy (leak rate) Depending on the test setup Depending on the test setup Typically 5% of the measured value, no smaller than 0.5% of the end value
Repeatability Depending on the test setup Depending on the test setup 0.5% of the measured value, no smaller than 0.05% of the end value (depending on the test setup)

Further accuracies, test pressures, control options, customer-specific protocols for higher-level data acquisition and evaluation systems on request